As per shown in the picture, the rag bolt must be grouted into the cement/concrete wall.
The bolts must be fixed to the cement/concrete wall.
Allow setting & checking than install it using nut and washer.
Measure tape, Keyhole or saber saw, Hammer, Glasses, Rags or Paper toweling, Drill (1/2 dia, drill bit or larger), Pencil, sealant, sharp knife or scissors.
Please Note : Please install it in a way that future removal from underneath the counter top is possible without damaging the counter top.
ITEM | PROBLEM | PROBLEM REASONS | CORRECTIVE ACTIONS |
Wash Basins / Table Top | 1. Overflow Chocked And Foul Bed Odor | Waste Coupling Used May Be Full Threaded | Waste Coupling Should Be Changed To Slot Cut Coupling |
2. Water Deposit On Tap Platform Area And Inside Bowl Area | Basin Is Not fixed in level or bracket is not in level | should be done by proper leveling | |
3. there is no tap hole in basin | tap hole could be semi punched from back side | tap hole should be created by plumber from semipunched area | |
Ewc / pan / anglo indian | 1. Water not coming in bowl area while flushing | flush bend is not inserted up to the end of inlet hole | insert the flush pipe up to the end of inlet ( for pan closet) check whether flush pipe is not covering flush hole which is in both side of inlet wall |
closet / pan may be not leveled | should be done by proper leveling | ||
one piece closet | 1. Water not coming in bowl area while flushing | mechanism inside tank could not working properly | change the centre pump of mechanism |
there is no water in flush tank | increase the ball cock height to the max level | ||
2. water is continuously leaking inside the bowl | mechanism inside tank could not working properly | change the centre pump of mechanism | |
3. water quantity insufficient for effective flushing | ball cock height adjusted at lower level | increase the ball cock height to the max level | |
4. uneven flow of water from both side of closet | closet is not leveled properly | closet should be in proper level | |
wallhung water closet | 1. Water not coming in bowl area while flushing | flush valve may not working properly / concealed cistern is not working properly | should change flush valve / concealed cistern |
flush pipe is not inserted up to the end of inlet hole | insert the flush pipe up to the end of inlet | ||
2. water is continuously leaking inside the bowl | closet is not leveled properly | closet should be in proper level | |
3. water quantity insufficient for effective flushing | connection between closet outlet and drainage pipe is not proper | should be done by proper connection by experienced plumber | |
couple closet ( 2 pcs closet ) | 1. uneven flow of water from both side of closet bowl | both arm of driverter pipe not inserted equally in both side of the closet | both arm of driverter pipe should be inserted equally in both side of the closet |
2. water is leaking between the cistern and closet | diverter pipe not fixed properly in the outlet of cistern | diverter pipe should be fixed properly in the outlet of cistern | |
rubber ring containing bolt is not tightened properly | rubber ring containing bolt should be tightened properly |